Solutions

Enclaves, gateways, and containment.

Enclaves isolate the workload. Gateways carry it to the public. Containment watches everything in between. All three inherit the same pre-approved baseline, so nothing here needs to be re-audited later.

Isolation enforced in silicon.

Hardware-isolated compute. Workload memory is encrypted by the processor with keys the hypervisor never holds, so a host operator cannot read guest memory in the clear. Isolation comes from the hardware rather than from a configuration an assessor has to verify and an operator has to keep correct.

Isolation
AMD SEV-SNP per-workload, hardware-enforced
Memory encryption
Processor-managed integrity-protected
Attestation
Signed measurement verified per boot
Baseline inherited
FedRAMP High NIST SP 800-53 Rev. 5

Built to stay up under any load.

Highly resilient front-end application portals and database bridges built to meet public-facing federal information system requirements, with a cryptographically signed, immutable record of every transaction that touches them.

Access controls
FedRAMP High system controls
Replication
Active-active across 3 metro markets
Audit trail
Cryptographically signed immutable, WORM-stored
Uptime SLA
99.99% contractual, service-credit backed

Threats are profiled before they're a problem.

A distributed honeypot/honeynet deception network and 24/7 SOC telemetry map attacker behavior and deploy countermeasures in real time, backed by ML-based behavioral threat detection and BGP-based DDoS scrubbing.

Deception network
50,000+ distributed honeypots
Edge defense
BGP-based DDoS scrubbing network-layer
Threat detection
ML behavioral analytics continuous
Requests scrubbed
2.8B+ cumulative, as of Q2 2026
Next steps

Take the next step

Every sector here inherits the same accredited baseline. The right entry point depends on what you are deploying and how far along the decision is.

Talk to a solutions architect

Not sure which sector fits your workload? A short session maps your application onto enclaves, gateways, and containment before you commit to a design.

Request a briefing

Check the hardware it runs on

Host specifications, facility locations, and the transit profile behind each of the three sectors, with no sign in required.

View infrastructure specs

Read the deployment guides

Provisioning, control mapping, and cutover procedures are published, so your engineers can assess the work before anyone signs anything.

Read the documentation

Take it to a site without a facility

All three sectors have a deployable form: a transit case, a rack module, or a container that ships as an approved extension of the same boundary.

Deployable data centers